| Model |
IE-3400-8T2S-A |
| Description |
Catalyst IE3400 with 8 GE Copper and 2 GE SFP, Adv. Modular, Network Advantage |
| Hardware configurations |
| Total ports |
10 |
| 10/100/1000 RJ45 Copper ports |
8 |
| 100/1000 SFP ports |
2 |
| 1GE/2.5G RJ45 Copper ports |
- |
| Software license |
Network Advantage |
| Hardware specification |
| PoE power budget |
Not applicable |
| Removable storage |
USB, SD card |
| Alarms |
2 alarms in, 1 alarm out |
| Console ports |
1 RS-232 (via RJ-45), 1 USB Mini Type B |
| Power inputs |
Dual DC power inputs |
| Physical configurations |
| Dimensions (H x W x D) |
6 in. X 3.6 in. X 5.3 in. 15.2 cm. x 9.1 cm. x 13.5 cm |
| Weight |
3.8 lbs 1.7 kg |
| Mounting |
DIN rail |
| Performance and scalability features |
| Forwarding rate |
Line rate for all ports and all packet sizes |
| Number of queues |
8 |
| Unicast MAC addresses |
16K |
| Internet Group Management Protocol (IGMP) multicast groups |
1K |
| No. of VLANs |
256 |
| IPv4 Indirect routes1 |
3000 |
| IPv6 Indirect routes1 |
512 |
| Spanning Tree Protocol (STP) instances |
128 |
| Access Control Entries (PACL/VACL/RACL) |
3K |
| DRAM |
4 GB |
| Flash [User Accessible] |
1.5 GB |
| SD card capacity2 |
4 GB, 16 GB |
| Jumbo Frames |
8996 bytes |
| Power specifications |
| Input voltage range |
Redundant DC input voltage: 9.6 to 60VDC |
| Input current |
6.3A |
| Power consumption |
36W |
| MTBF (hours) |
549.808 |
| Network Advantage License (Perpetual) |
| IP routing Protocols |
OSPF (IPv4 and IPv6), BGP (v4 and v6), ISIS (v4 and v6), RIP (v1 and v2), EIGRP (v4 and v6), Policy based routing (PBR), VRRP (v4 and v6), HSRP (v4 and v6), BFD Echo Mode for OSPFv3 |
| Virtualization |
Vrf-lite, VRF-Aware SGT |
| Security |
MACsec-256, SGT/SGACL1,Cisco TrustSec |
| IP Multicast |
PIM sparse mode (PIM-SM), PIM dense mode (PIM-DM), MSDP, Multicast routing BSR (IPv4/IPv6), Auto RP (IPv4), Embedded RP (IPv6) |
| All Network Essentials features. |
Network Advantage License includes all Network Essentials features. |
| Compliance Specifications |
| Industrial Automation Control System |
IEC 62443-4-1
IEC 62443-4-2 |
| Electromagnetic emissions |
FCC 47 CFR Part 15 subpart B Class A
EN 55032/CISPR 32 Class A
VCCI Class A
AS/NZS CISPR 32 Class A
CISPR 11 Class A
ICES 003 Class A
CNS 13438 Class A3
KN 32 Class A3
EN 300 386 |
| Electromagnetic immunity |
CISPR 24 / CISPR 35
EN55024/ EN55035
KN 35
EN 61000-4-2 Electro Static Discharge (air – 15kV, contact – 8kV)
EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP)
EN 61000-4-4 Electromagnetic Fast Transients (4kV)
EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP)
EN 61000-4-6 Conducted RF (10Vrms UTP)
EN 61000-4-8 Power Frequency Magnetic Field (1000A/m)
EN 61000-4-10 Damped Oscillatory Magnetic Field (100 A/m)
EN 61000-4-16 Conducted CM Disturbances (30V, Cont/ 300V, 1 sec)
EN 61000-4-17 Ripple Immunity DC Power (10%)
EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz)
EN-61000-4-29 DC Voltage Dips and Interruptions |
| Industry standards |
EN 61000-6-2 Industrial Immunity
EN 61000-6-4 Industrial Emissions
EN 61000-6-1 Light Industrial Immunity
EN 61326-1 Measurement, Control and Laboratory Equipment
EN 61131-2 (EMC - Emission and Immunity)
IEEE 1613 Electric Power Stations Communications Networking
EN/IEC 61850-3 Electric Substations Communications Networking
ODVA Industrial EtherNet/IP
NEMA TS 2-2016
AREMA C and S section 11, 19
IP30 |
| Marine I |
DNV Certification according to class guideline DNV-CG-0339
Additional Standards:
IEC 60945, IACS UR E10
Marine DNV GL – Ships; High speed and light craft |
| Safety standards and certifications |
Information Technology Equipment:
UL/CSA 60950-1, IEC 60950-1 CB with all country deviations
UL/CSA 62368-1, IEC 62368-1 CB with all country deviations
Industrial floor (control equipment):
UL/CSA 61010-2-201
CB report and certificate to IEC/EN 61010-2-201
Hazardous locations:
UL121201(Class l, Div 2, groups A-D)
CSA 213 (Class l, Div 2, groups A-D)
UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC)
IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC)
EN 60079-0, -15 ATEX certificate (Class l, Zone 2, Gc/IIC) Cabinet enclosure required |
| Operating environment |
Operating temperature:
-40°C to +70°C (40 LFM vented enclosure)
-40°C to +60°C (sealed enclosure)
-40°C to +75°C (Min. 200 LFM fan or blower-equipped enclosure)
+85°C (type tested for 16 hours)
Altitude: up to 15,000 feet |
| Storage environment |
Temperature: -40°C to +85°C degrees
Altitude: 15,000 feet
IEC 60068-2-14 |
| Humidity |
Relative humidity of 5% to 95% non-condensing
IEC 60068-2-78
IEC 60068-2-30 |
| Shock and vibration |
IEC 60068-2-27 (operational shock, 50G, 3ms, half sine)
IEC 60068-2-27 (non-operational shock, 65-80G, 9ms, trapezoidal)
MIL-STD-810, Method 514.4
IEC 60068-2-6 (vibration-sinusiodal, 5Hz-150Hz) |
| Corrosion |
IEC 60068-2-52 (salt fog)2
IEC 60068-2-60 (flowing mixed gas)2 |
| Railway |
EN50125-1: 2014
EN50125-3: 2003
EN50121-4 Railway – Signaling and Telecommunications Apparatus
EN50121-3-2 / EN50155 (EMC) |
| Warranty |
Five-year limited hardware warranty on all IE3300 product IDs and all Industrial Ethernet (IE) power supplies. See more information under the Warranty section |